When the air compressor is running, the outlet pressure is too low, which affects the production demand. As a result, the outlet pressure of the air compressor is too low. There are many factors: ◆1. The air volume of the air compressor is too large. It is generally recommended that the customer check the pipeline for leaks; ◆2, the intake valve failure of the air compressor causes the valve opening to be insufficient. First remove the intake valve or maintain the repair kit; ◆3, the air intake valve of the air compressor controls the air supply leakage, causing the valve opening to be insufficient or unable to open. The leaking part needs to be excluded; ◆4. The pressure switch of the air compressor sets the working pressure too low. The upper pressure limit should be adjusted upwards; ◆5, the pressure switch failure of the air compressor causes the working pressure error. We need to overhaul the pressure switch, if it can't be repaired, replace it with new ones; ◆6, the computer pressure setting of the air compressor is too low or the pressure transmitter is faulty. First adjust the computer settings, and do the pressure transmitter, calibration, if the transmitter fails, replace the new product; ◆ 7, air compressor load solenoid valve failure, air leakage caused by insufficient control air supply. First remove the load solenoid valve for repair and repair, if it can not be repaired, replace the new product; ◆8, the air filter of the air compressor is blocked. First remove the air filter and maintain it. If the filter is blocked, replace it with a new one. ◆9. The air separator of the air compressor is blocked. First check whether the differential pressure of the oil separator has reached 0.8-1kg, and if so, replace the new product; ◆10, the belt driven by the air compressor is too loose, resulting in a decrease in transmission efficiency. Need to adjust the drive belt, if it is damaged, replace the new product; ◆11, the air intake valve of the air compressor is worn out, causing insufficient opening. Need to replace the intake coupling; ◆12, the efficiency of the synchronous motor of the air compressor is reduced, resulting in insufficient opening. Need to replace the synchronous motor with a new one). Label [air compressor outlet pressure is too low and its treatment method] [What should I do if the screw air compressor pressure is insufficient?]

Recommended product:3 cubic screw air compressor 6 cubic screw air compressor10 cubic screw air compressor